Description
The C3510 automatic coagulometer is a fully automated, high-throughput, state-of-the-art, compact and highly reliable analyser for haemostasis testing.
The C3510 analyser incorporates the latest optical technologies to enable measurements based on cloning, chromogenic and immunological detection methods
Advantages of C3510 Mindray
- 4 folding channels.
- 6 independent optical channels.
- Fully automated system:
• automatic sampling;
• automatic measurement;
• automatic control of the working environment temperature;
• automatic generation of a measurement report;
• automatic printing of results;
• automatic monitoring of the use of reagents and consumables. - High throughput – 300 tests per hour.
- Automatic cuvette loading – 1,000 cuvettes in the autoloader.
- Automatic calibration by 2-6 points.
- Support for pre-defined automatic sample selection and the identification of «emergency medical care» cases.
- High reproducibility of results (coefficient of variation CV less than 3%).
- Low cost per analysis.
Features of the Mindray C3510 coagulometer
- Low flushing solution consumption, convenient tank location that makes it easy to control the flushing liquid level.
- The ability to configure experimental parameters online (in real time).
- Built-in barcode scanner.
- Supports automatic error reporting and correction during testing.
| Parameters under study | Prothrombin time and estimated fibrinogen Partially activated platelet time Thrombin time Fibrinogen Coagulation factors, II, V, VII, VIII, IX, X, XI, XII Antithrombin III Lupus anticoagulants (screening, confirmation) Heparin D-dimer Protein S Protein C FDP Resistance to activated protein C, etc. |
| Positions for reagents | 24 reagent positions with LED indicator and cooling function + 4 without cooling 5 positions with stirring function |
| Sample positions | 80 positions + 3 STAT positions |
| Testing channels | 4 folding channels 5 optical channels at 575 nm 1 optical channel 405 nm |
| Measurement principle | Clotting method Mechanical method (double magnetic ball method) The chromogenic method Immunological method |
| General parameters | Weight – 62 kg Dimensions (L x W x H, in mm) – 585 × 695 × 590 Power supply: AC 230V, 50Hz |
| Productivity | Up to 300 tests/hour |
| Forklift truck | Maximum capacity – 1,000 cuvettes |
| Quality control | Building Levy-Jennings graphs Conducting an audit according to the Westgarde rules |
| Controlling the analyser | Standalone Computer (included) |
| Interface. | Standard RS232 Languages – English, Ukrainian |
| Printer | Built-in Included with the computer |
| Environmental conditions | Temperature – 10–30 ⁰C Humidity – not exceeding 70% Atmospheric pressure – 86 kPa – 106 kPa |