Automatic coagulometer C3510 Mindray

SPECIFY PRICE

The C3510 automatic coagulometer is a fully automated, high-throughput, state-of-the-art, compact and highly reliable analyser for haemostasis testing.
The S3510 analyser incorporates the latest optical technologies, enabling measurements based on chemiluminescent, chromogenic and immunological detection methods.

  • 4 folding channels.
  • 6 independent optical channels.
  • Fully automated system:
    • automatic sampling;
    • automatic measurement;
    • automatic control of the working environment temperature;
    • automatic generation of a measurement report;
    • automatic printing of results;
    • automatic monitoring of the use of reagents and consumables.
  • High throughput – 300 tests per hour.
  • Automatic cuvette loading – 1,000 cuvettes in the autoloader.
  • Automatic calibration by 2-6 points.
  • Support for pre-defined automatic sample selection and the identification of «emergency medical care» cases.
  • High reproducibility of results (coefficient of variation CV less than 3%).
  • Low cost per analysis.

Description

The C3510 automatic coagulometer is a fully automated, high-throughput, state-of-the-art, compact and highly reliable analyser for haemostasis testing.
The C3510 analyser incorporates the latest optical technologies to enable measurements based on cloning, chromogenic and immunological detection methods

Advantages of C3510 Mindray

  • 4 folding channels.
  • 6 independent optical channels.
  • Fully automated system:
    • automatic sampling;
    • automatic measurement;
    • automatic control of the working environment temperature;
    • automatic generation of a measurement report;
    • automatic printing of results;
    • automatic monitoring of the use of reagents and consumables.
  • High throughput – 300 tests per hour.
  • Automatic cuvette loading – 1,000 cuvettes in the autoloader.
  • Automatic calibration by 2-6 points.
  • Support for pre-defined automatic sample selection and the identification of «emergency medical care» cases.
  • High reproducibility of results (coefficient of variation CV less than 3%).
  • Low cost per analysis.

Features of the Mindray C3510 coagulometer

  • Low flushing solution consumption, convenient tank location that makes it easy to control the flushing liquid level.
  • The ability to configure experimental parameters online (in real time).
  • Built-in barcode scanner.
  • Supports automatic error reporting and correction during testing.
Parameters under study Prothrombin time and estimated fibrinogen
Partially activated platelet time
Thrombin time
Fibrinogen
Coagulation factors, II, V, VII, VIII, IX, X, XI, XII
Antithrombin III
Lupus anticoagulants (screening, confirmation)
Heparin
D-dimer
Protein S
Protein C
FDP
Resistance to activated protein C, etc.
Positions for reagents 24 reagent positions with LED indicator and cooling function + 4 without cooling
5 positions with stirring function
Sample positions 80 positions + 3 STAT positions
Testing channels 4 folding channels
5 optical channels at 575 nm
1 optical channel 405 nm
Measurement principle Clotting method
Mechanical method (double magnetic ball method)
The chromogenic method
Immunological method
General parameters Weight – 62 kg
Dimensions (L x W x H, in mm) – 585 × 695 × 590
Power supply: AC 230V, 50Hz
Productivity Up to 300 tests/hour
Forklift truck Maximum capacity – 1,000 cuvettes
Quality control Building Levy-Jennings graphs
Conducting an audit according to the Westgarde rules
Controlling the analyser Standalone
Computer (included)
Interface. Standard RS232
Languages – English, Ukrainian
Printer Built-in
Included with the computer
Environmental conditions Temperature – 10–30 ⁰C
Humidity – not exceeding 70%
Atmospheric pressure – 86 kPa – 106 kPa

Additional information

Positions for reagents

24 reagent positions with an LED indicator and a cooling function + 4 without cooling; 5 positions with a mixing function

Sample positions

80 positions + 3 STAT positions

Testing channels

4 convolution channels, 5 optical channels at 575 nm, 1 optical channel at 405 nm

Measurement principle

Clotting methodMechanical method (double magnetic bead method)Chromogenic methodImmunological method

General parameters

Weight: 62 kg. Dimensions (L x W x H, in mm): 585 × 695 × 590. Power supply: AC 230 V, 50 Hz

Productivity

Up to 300 tests/hour

Forklift truck

Maximum loading capacity 1000 cuvettes

Quality control

Plotting Levi–Jennings graphs; Performing a test according to Westgaard’s rules

Controlling the analyser

Standalone computer (included)

Interface.

Standard RS232 Languages: English, Ukrainian

Printer

Built-in. Included with the computer

Environmental conditions

Temperature 10–30 ⁰C; Humidity not exceeding 70%; Atmospheric pressure 86 kPa – 106 kPa