Mindray vetXpert I3 Veterinary Immunofluorescence Analyser

SPECIFY PRICE

Description

All-in-One Comprehensive Analysis

The vetXpert I3 veterinary immunological analyser operates on the basis of immunochromatography and is used clinically for the quantitative or semi-quantitative detection of analytes in animal body fluids (such as whole blood, serum, plasma, pre-processed eye, nose and throat swabs, faeces, etc.), including antigens, antibodies, hormones, enzymes and infectious diseases.

Specifications of the vetXpert I3 analyser

Usage inflammation, pancreatitis, kidney disease, hormones, cardiac markers, infectious diseases, antibody titres
Types of animals cats, dogs
Sample type whole blood, serum, plasma, conjunctival/throat/nasal swabs and faecal swabs
Test mode standard mode, quick test mode
Testing time 5–15 minutes
Display. 7-inch TFT touchscreen
Interface. USB and LAN support for bidirectional LIS
Working environment Temperature: 15–32 °C

Humidity: 20 – 85%

Power supply 100–240 V, 50/60 Hz
Weight 4.2 kg
Dimensions 195 × 275 × 250 mm

A full range of immunological tests for the analyser

We offer a full range of immunological tests for in-house use. The tests are used to assess inflammation, pancreatitis, kidney disease, cardiac markers, hormones, infectious diseases, antibody titres, tick-borne diseases and more.

A wide range of tests for all illnesses

Inflammation cCRP, fSAA
Pancreatitis cPL, fPL
Kidney disease cSDMA, fSDMA
Hormones cCortisol, cT4, fT4, cTSH, cProg
Cardiological markers cTnI, fTnI, cNT pro-BNP, fNT pro-BNP
Antibody titres Ab: CAV CDV CPV

Ab: FPV, FHV, FCV

Infectious diseases FeLV Ag, FIV Ab, FCoV Ag, FPV Ag, CCV Ag, CIV Ag, CPV Ag,

CDV Ag, Giardia Ag, Toxoplasma Ab, HW Ag, E. canis Ab, Anaplasma Ab, Lyme Ab

Others cD-dimer

 

Reagents that can be stored at room temperature and are easy to store and use

  • Store at 4–30 °C
  • No heating required; ready to use once opened

Genuine POCT tests

  • Test duration: 5–15 minutes
  • Shorter waiting times

High-quality machine-readable tests

  • Two testing methods
  • High-quality tests that can be read by a machine, with the results printed out
  • A more accurate test using a smaller sample

Effective and easy to use

  • Non-slip design, easy to hold
  • A QR code containing calibration information, which is automatically recognised by the analyser

Ease of use

Step 1

Add a sample to the cartridge well

Step 2

Select a test mode

Step 3

Insert the test cartridge into the analyser and wait 5–15 minutes

Interpretation of the results

Positive

The test is positive if two lines are visible (the control line C and the test line T).

Negative

The test is negative if only the C control line is present.

Invalid

The test is invalid if there is no line on the control line (C), even if a line is present on the test line (T).

 

Step 4

Print report

Leave a request or contact us in any way convenient for you.