Electrocardiograph NEO ECG T180 Carewell

70 020.00 

10.1" high-resolution colour touchscreen, easy to operate. Portable design, compact size.
High accuracy. Tested on 1000000 independent MIT test data, the average accuracy of the AI-ECG platform reaches 95.2%.
High analysis speed. 1 second for automatic ECG analysis can rest easy. The time saved can reduce the overall clinical ECG analysis time.
Comprehensive diagnostics Supports 16 types of cardiology classification, 104 types of ECG diagnostic classifications.

SKU: NEO ECG T180 Carewell Categories: ,

Description

About the NEO ECG T180 Carewell electrocardiograph:

  • High-resolution 10.1" colour touchscreen, easy to use. Portable design, compact size;
  • Operation from an external DC power source, built-in lithium rechargeable battery;
  • Supports synchronous acquisition and display of 9/12-lead waveforms, as well as heart rate detection;
  • Supports automatic tempo detection and labelling;
  • Supports automatic mode, HR, HRV analysis, drug test, ECG event mode;
  • Provides 4 sampling modes: pre-sampling, real-time sampling, periodic sampling, and triggered sampling;
  • Supports automatic rhythm detection;
  • Enter patient information using a virtual alphanumeric keyboard and barcode scanning;
  • Freeze the ECG waveform on the screen;
  • Output files can be saved in a variety of formats, such as Carewell ECG, PDF, BMP, HL7, DICOM, SCP;
  • Easily search patient data, save, view, edit, export, download and print;
  • Supports wireless ECG data transmission via WiFi and mobile networks;
  • Base with built-in thermal printer and support for an external laser printer;
  • Export patient data to a USB flash drive via the USB connector;
  • Supports controlling user login permissions, using a password, or authenticating an account and password to use the device;
  • Supports online and offline login to the device, as well as viewing patient data in the ward history according to the login account;
  • Supports connection to AI-ECG PLATFORM to achieve intelligent diagnostics (Optional).

Advantages of NEO ECG T180 Carewell:

1. Two print modes

  • Use of the built-in thermal printer located on the base of the recorder;
  • Supports direct WiFi or USB connection to a laser printer Convenient A4 format for printing ECG diagnostic reports.

2. Lightweight and portable 2 in 1 ECG device

  • The thickness of the product is 27 mm;
  • The weight of the device is 1.2 kg;
  • Weighing 2.5 kg, the lightweight and portable ECG is a breakthrough among traditional devices due to its incredible convenience.

3. Multi-lead ECG mode

  • Supports synchronous acquisition and display of 9/12-lead waveforms, as well as heart rate detection.

4. Supports automatic tempo detection and labelling

  • The device effectively monitors the patient's ECG before, after and during surgery. Full ECG analysis, and up to 30 minutes of resting ECG collection.

5. Full screen touch

  • 10-inch colour touchscreen with high resolution (1280x800), convenient tablet ECG design, easy operation.
Type 10.1-inch tablet
Size 72.6 mm (L) * 181.2 mm (W) * 25.8 mm (H)
Net weight 1.2 kg
Base. 10.1 inches (optional)
Size 274 mm (L) * 288 mm (W) * 111.2 mm (H)
Net weight 2.5 kg
Analysis algorithm Glasgow
Heart rate range 30~300 strokes per minute
Accuracy ±1
Withdrawal 9,12
A / D conversion 24 bits
Sample rate 32000 samples/sec
Common mode failure rate ≥140 dB (AC filter on) ≥120 dB (AC filter off)
Time constant ≥5 с
Frequency response 0.01 Hz ~ 350 Hz (+0.4 dB-3.0 dB)
Sensitivity Auto, 2.5 mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV, error less than ±5%
Filter. AC filter: 50 Hz, 60 Hz, off
EMG filter: 25 Hz, 35 Hz, 45 Hz, off
ADS filter: 0.01 Hz, 0.05 Hz, 0.32 Hz, 0.67 Hz
Low-pass filter: 75 Hz, 100 Hz, 150 Hz, 300 Hz, off
Paper speed 5 mm/s, 6.25 mm/s, 10 mm/s, 12.5 mm/s, 25 mm/s and 50 mm/s, error less than ±3 %
Input impedance ≥100 MΩ (10 Hz)
Input circuit current ≤10nA
Calibration voltage 1 mV±2%
Depolarisation voltage ±900 mV, ±5%
Noise ≤12.5 µV
Amplitude quantisation 0.95 µV/LSB
Recovery time after a defibrillation shock <10 с
Pacemaker pulse display A stimulation pulse with an amplitude of ±2mV~±700mV, a duration of 0.1ms~2.0ms, an A-5 rise time of less than 100µs and a frequency of 100/min can be displayed on the ECG recording.
The minimum signal that can be detected 20 µVp-p

Additional information

Type

10.1-inch tablet

Base.

10.1 inches (optional)

Size

274 mm (L) * 288 mm (W) * 111.2 mm (H)

Net weight

2.5 kg

Analysis algorithm

Glasgow

heart rate range

30~300 strokes per minute

Accuracy

±1

Withdrawal

9,12

A / D conversion

24 bits

Sample rate

32000 samples/sec

Common mode failure rate

≥140 dB (AC filter on) ≥120 dB (AC filter off)

Time constant

≥5 с

Frequency response

0.01 Hz ~ 350 Hz (+0.4 dB-3.0 dB)

Sensitivity

Auto, 2.5 mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV, error less than ±5%

Filter.

AC filter: 50 Hz, 60 Hz, off

Paper speed

5 mm/s, 6.25 mm/s, 10 mm/s, 12.5 mm/s, 25 mm/s and 50 mm/s, error less than ±3 %

Input impedance

≥100 MΩ (10 Hz)

Input circuit current

≤10nA

Calibration voltage

1 mV±2%

Depolarisation voltage

±900 mV, ±5%

Noise

≤12.5 µV

Amplitude quantisation

0.95 µV/LSB

Recovery time after a defibrillation shock

<10 с

Pacemaker pulse display

A stimulation pulse with an amplitude of ±2mV~±700mV, a duration of 0.1ms~2.0ms, an A-5 rise time of less than 100µs and a frequency of 100/min can be displayed on the ECG recording.

The minimum signal that can be detected

20 µVp-p