Mindray BS-600M automatic biochemical analyser with ISE

SPECIFY PRICE

Capacity - 600 tests/hour. 124 positions for reactions, 80 positions for reagents, and 120 positions for samples with continuous rack loading. Sample volume: 1.5 μL~45 μL, 0.1 μL step; reagent volume: 10 μL~200 μL, 0.5 μL step; reaction mixture volume: 70~300 μL. 16 wavelengths: 340 to 850 nm.

Description

BS-600M from Mindray - is a computer-controlled, high-precision automated system for clinical blood testing. The device measures a number of biochemical parameters and prevents human error due to the accuracy of its results.

Features of the BS-600M Mindray biochemical analyser:

1. Managing the reaction 

  • 124 plastic or permanent glass cuvettes;
  • 70-300 µl is a low reaction volume;
  • dry bath;
  • lamp - 2000 hours, 16 wavelengths.

2. Sample management: 

  • automatic repetition without manual intervention;
  • 120 samples, their continuous loading by means of racks;
  • 30 STAT sample positions, start in just 1 minute;
  • The calibrator and reference target value are entered using intelligent QR code scanning, which helps to increase efficiency and eliminate human error;
  • Specially designed sample tray for transferring samples.

3. Management of reagents:

  • 80 positions with cooling system (2-8℃);
  • separate reagent loading window, support for on-board reagent loading;
  • supports whole blood HbA1c analysis;
  • higher level of anti-interference from hemoglobin variants.

Advantages of the BS-600M Mindray biochemical analyzer:

  • High performance - 600 tests per hour;
  • The minimum sample volume is from 1.5 µl;
  • Efficient washing system. Internal and external washing reduces sample transfer. Available rinsing options: special alkaline, special acid and standard;
  • Automatically checks the cleanliness of reaction cuvettes before analysis;
  • Control of the amount of reagents on board;
  • Intelligent mixing system;
  • The point light source reduces the minimum reaction volume to 70 µl and maximises cost-effectiveness;
  • Extended lamp life with automatic shut-off function;
  • The reliable direct heating system stabilises the reaction temperature at 37 °C;
  • 24-hour cooling keeps the temperature of the reagent compartment between 2 and 8 °C;
  • Online monitoring of the reaction progress;
  • There are 2 reagent probes available, which are equipped with level detection, horizontal and vertical obstruction detection, and air bubble detection;
  • The probe is cleaned from the inside and outside;
  • A statistical data processing programme;
  • The system is equipped with a workstation.

 

Principles of analysis Colourimetry, turbidity
Types of reactions Endpoint, fixed time and kinetics
Reagent mode Support for tests using one, two, three or four reagents
Wavelength Support for dual-wavelength mode
Sample volume 1.5 µl ~ 45 µl, 0.1 µl steps
Reagent volume 10 µl ~ 200 µl, 0.5 µl steps
Volume of the reaction mixture 70 ~ 300 µl
Reaction carousel 124 positions
Reagent carousel 80 items
Sample carousel 120 positions, with the option of continuous loading of the racks
Reaction temperature 37 °C ± 0.1 °C
Heating mode Dry bath
Flushing unit Two-level 8-phase rinsing
Water consumption 42 l/h at continuous flow, and 2 l/h at short-term maximum flow
Light source Halogen lamp with a tungsten filament, 12 V/20 W
Wavelength 16 wavelengths: 340, 380, 412, 450, 480, 505, 546, 570, 605, 630, 660, 700, 740, 770, 800 and 850 nm

The price of the equipment is included:

1) VAT;
2) Staff training;
3) Warranty service: 12 months from the date of commissioning;
4) Service support and methodological support during the warranty period;
5) After the end of the warranty period, the opportunity to conclude a service agreement - priority in service and resolution of service issues;
6) A set of reagents for launching the device and training personnel;
7) a computer station, printer and UPS.

Additional information

Principles of analysis

Colourimetry, turbidity

Types of reactions

Endpoint, fixed time and kinetics

Reagent mode

Supports tests with one, two, three, four reagents

Sample volume

1.5 µl ~ 45 µl, 0.1 µl steps

Reagent volume

10 µl ~ 200 µl, 0.5 µl steps

Volume of the reaction mixture

70 ~ 300 µl

Reaction carousel

124 positions

Reagent carousel

80 items

Sample carousel

120 positions, possibility of continuous loading of racks

Reaction temperature

37 °C ± 0.1 °C

Heating mode

Dry bath

Flushing unit

Two-level 8-phase rinsing

Water consumption

42 l/h at continuous flow, and 2 l/h at short-term maximum flow

Light source

Halogen lamp with tungsten filament, 12V/20W

Wavelength

16 wavelengths: 340, 380, 412, 450, 480, 505, 546, 570, 605, 630, 660, 700, 740, 770, 800 and 850 nm