Automatic biochemical analyser BS-430 Mindray

SPECIFY PRICE

Automatic analyser, "closed" reagent system. Productivity - 420 tests per hour. Advanced optical system. 12 wavelengths (340nm to 800nm), support for two-wavelength reaction method and 1-2 reagent tests. Reaction carousel - 93 positions, minimum volume of reaction mixture - 100 µl. Single reusable cuvette. Efficient automatic cuvette washing system. Full-cycle HbA1 technology. The system is equipped with a workstation.

Description

The main thing, What you need know about BS-430

  1. Automated high-precision system controlled by a computer.
  2. 90 photometric tests + 3 ISE (3 indicators in serum and urine samples) + 3 serum indicators.
  3. High throughput - 420 tests per hour (up to 620 for ISE)
  4. Full provision of the analyser with all necessary reagents, control and consumables, calibrators by the equipment manufacturer.

Advantages.and BS-430 Mindray

  • High performance - 420 tests per hour.
  • The highly polished probes are equipped with combined technologies to ensure accuracy and reliability. The minimum sample volume is from 1.5 µl.
  • Efficient washing system. Internal and external washing reduces sample transfer. Pre-heated deionised water and detergent ensure perfect cuvette cleanliness.
  • Intelligent mixing system. Stepper motors with speed control optimise the mixing effect.
  • Advanced optical system. Advanced grating photometer technology effectively reduces stray light and increases the accuracy of test results. A point light source reduces the minimum reaction volume to 100 µl and maximises cost-effectiveness. Extended lamp life with automatic shutdown function.
  • Reliable heating system. Direct heating technology stabilises the reaction temperature at 37 °C. 24-hour cooling keeps the reagent compartment temperature between 2 and 8 °C.
  • Updated software control. Inherited from high-end Mindray products, the user-friendly software combines more practical functions and is easier to use. Step-by-step
  • a maintenance manual for laboratory technicians.
  • A complete solution for clinical chemistry. Designed to provide a complete clinical chemistry solution with traceability to ensure maximum accuracy of test results.
  • Optimised integration of the entire system. All parameters are optimised during integration to maximise the reliability of test results.
  • Intelligent HbA1c dosing with intelligent sampling technology enables on-board haemolysis for HbA1c

Features.

  • The minimum volume of the reaction mixture is 100 µl;
  • Productivity up to 420 tests per hour;
  • Automatically checks the cleanliness of reaction cells before analysis;
  • Online monitoring of the reaction progress;
  • The reagent dispenser preheats reagents, detects reagent and sample levels, monitors levels, and is protected against vertical collisions;
  • Control of the amount of reagents on board;
  • Continuous cooling function, which is independently powered from other analyzer systems and can operate 24 hours a day;
  • The probe is cleaned inside and out!
  • A statistical data processing programme;
  • The system is equipped with a workstation;

TECHNICAL SPECIFICATIONS

Principles of analysis Colourimetry, turbidity, ISE method
Types of reactions Endpoint, fixed time and kinetics
Reagent mode Support for single/dual reagent tests
Wavelength Support for dual-wavelength mode
Sample volume for routine chemical analysis 1.5 µl ~ 45 µl, 0.1 µl steps
Reagent volume 10 µl ~ 200 µl, 0.5 µl steps
Reaction carousel There are 93 positions
Reaction temperature 37 °C ± 0.1 °C
Heating mode air bath
Reaction cuvette Single cuvettes, 5 mm × 5 mm × 29.5 mm (length × depth × height), reusable cuvettes
Flushing unit Vertical obstacle detection function (optional)
Light source Tungsten halogen lamps 12 V 20 W
Wavelength 340 nm – 800 nm (12 wavelengths)
The amount of reaction 100 ~ 300 µl
Dimensions (LxWxH) ≤ 1050 mm (W) * 720 mm (D) * 1150 mm (H)
Weight ≤200 kg

The price of the equipment is included:

  • VAT
  • Staff training
  • Warranty service: 12 months from the date of commissioning
  • Service support and methodological support during the warranty period
  • After the end of the warranty period, the opportunity to conclude a service agreement - priority in servicing and resolving service issues.

Additional information

Principles of analysis

Colourimetry, turbidity, ISE method

Types of reactions

Endpoint, fixed time and kinetics

Reagent mode

Support for single/dual reagent tests

Sample volume for routine chemical analysis

1.5 µl ~ 45 µl, 0.1 µl steps

Reagent volume

10 µl ~ 200 µl, 0.5 µl steps

Reaction carousel

There are 93 positions

Reaction temperature

37 °C ± 0.1 °C

Heating mode

Air bath

Reaction cuvette

Single cuvettes, t. 5 mm × 5 mm × 29.5 mm (length × depth × height), reusable cuvettes

Flushing unit

Vertical obstacle detection function (optional)

Light source

Tungsten halogen lamps 12 V 20 W

Wavelength

340 nm - 800 nm, (12 wavelengths)

The amount of reaction

100 ~ 300 µl

Dimensions (LxWxH)

≤ 1050 mm (W) * 720 mm (D) * 1150 mm (H)

Weight

≤200 kg