Patient monitor K15 Multi-Gas Creative Medical

487 800.00 

The Creative Medical K15 Multi-Gas Patient Monitor is a multifunctional device for precise monitoring of blood gas and other vital signs. Bedside K15 patient monitors from Creative Medical are designed to measure and monitor basic physiological parameters of the patient. With real-time recording and display of parameters such as ECG, heart rate, non-invasive blood pressure, functional oxygen saturation, body temperature, etc., it allows for a comprehensive analysis of the patient's physiological conditions.

SKU: K15 Multi-Gas Creative Medical Categories: ,

Description

Bedside tables K15 patient monitors from Creative Medical are designed to measure and monitor basic physiological parameters of the patient. With real-time recording and display of parameters such as ECG, heart rate, non-invasive blood pressure, functional oxygen saturation, body temperature, etc., it allows for a comprehensive analysis of the patient's physiological conditions.

Features of the K15 Multi-Gas Creative Medical:

  • the device measures the concentration 15 anaesthetic gases;
  • large colour display with wide viewing angles;
  • are equipped with an automatic measurement function and do not require preliminary settings;
  • defibrillator discharge protectionresistance to interference from the electrosurgical unit; detection and inhibition of pacemaker pulses;
  • the ability to connect to a network for central monitoring;
  • automated calculation function for clinical use - calculator of oxygen, drugs, haemodynamics, respiration, renal function.

Additional information

Display.

15-inch TFT touchscreen display

Printing

Available

Input dynamic range of the ECG

± 0.5 ~ 5 mV

ECG type

3-channel

ECG bandwidth

0.05 ~ 150 Hz (diagnostics)
0.5 ~ 40 Hz (monitoring)
1 ~ 20 Hz (operation)

Measurement of heart rate (HR)

15 ~ 350 bpm, ± 1% or ± 2 bpm
Pacemaker pulse detection and rejection function

RESP measurement range

0 ~ 120 rpm ± 5% or ± 2 rpm

TEMP measurement range

21.0 ~ 50.0 °C ± 0.2 °C

NIBP (non-invasive blood pressure) measurement method and range

Oscillometric method
0 mmHg ~ 300 mmHg ± 3 mmHg

Measurement of invasive blood pressure 2 - IBP

50 mmHg ~ 300 mmHg

Monitoring of anaesthetic gases

15 anaesthetic gases

SpO2 measurement method and range

Double wavelength optical method 0% ~ 100% ± 2%

PR heart rate measurement range

30 ~ 250 bps ± 2 bps or ± 2%,

Battery

4400 mAh

Signalling method

3-level audible and visual alarms

Leave a request or contact us in any way convenient for you.